Hero

FSRI Releases Part I of the Fire Attack Study - Water Mapping

December 4, 2017

The Fire Safety Research Institute (FSRI), part of UL Research Institutes is pleased to release the scientific report and online training program from Part I of the 2013 DHS FEMA Grant, Impact of Fire Attack Utilizing Interior and Exterior Streams on Occupant Survival: Water Mapping.

This report and associated online training detail the results and analysis from a series of experiments, using fire service hose streams, conducted without the presence of fire, to gain a fundamental understanding of water distribution within a compartment.

“These results will aid firefighters in understanding where water is going during various application methods along with allowing them to better understand how tactical choices such as hose stream type, nozzle movement patterns, pressures/flow rates, stream locations and elevation angles effect water distribution.”

- Steve Kerber, Vice President, Research and Director, FSRI

Click here to download the report.

Click here to access the online training. 

Abstract

As research continues into how fire department interventions affect fire dynamics in the modern fire environment; questions continue to arise on the impact and implications of interior versus exterior fire attack on both firefighter safety and occupant survivability. Previous research into various types of fire ground ventilation, flow paths, and exterior fire streams has provided the fire service with an increased understanding of fire dynamics. However, in some instances, the information from the studies may not support current, experienced-based practices. This gap between the research to date and the fire ground suppression experience has driven the need for further study. Therefore, research into the various methods of fire attack will allow a broader understanding of how firefighter interventions on the fire ground can impact the outcome of both life safety and property protection.

This study will build upon the fire research conducted to date by analyzing how firefighting tactics, specifically different fire suppression tools and tactics, affect the thermal exposure and survivability of both firefighters and building occupants and affect fire behavior in structures. The purpose of this study is to improve firefighter safety, fireground tactics, and the knowledge of fire dynamics by providing the fire service with scientific information, developed from water flow and full-scale fire testing, in representative single-family homes. The project is comprised of 3 parts:

Part I: Water Distribution
Part II: Air Entrainment
Part III: Full-Scale Residential Fire Experiments

This report details the results and analysis from the water distribution experiments. These tests were conducted without the presence of fire to gain a fundamental understanding of water flows into compartments. Each test was designed to quantify water distribution within a compartment by evaluating the differences caused by various application methods, hose stream types, nozzle movements, pressures/flow rates, stream locations and elevation angles.


Research Project: Study of the Impact of Fire Attack Utilizing Interior and Exterior Streams on Firefighter Safety and Occupant Survival
Report Title: Impact of Fire Attack Utilizing Interior and Exterior Streams on Firefighter Safety and Occupant Survival: Water Mapping
Report Authors: Craig Weinschenk, Keith Stakes and Robin Zevotek
Download the Report: https://dx.doi.org/10.54206/102376/NEVX1787
Release Date: December 6, 2017

Study of the Impact of Fire Attack Utilizing Interior and Exterior Streams on Firefighter Safety and Occupant Survival